EasyManuals Logo

Goodwe GW10K-ET User Manual

Goodwe GW10K-ET
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
8
03 Product Introduction User Manual V1.1-2022-12-20
3.2 Application Scenarios
Supported Grid Types
WARNING
The PV system is not suitable to connect equipment that relies on a stable power supply,
such as medical equipment to sustain life. Ensure that no personal injury is occurred when
the system is disconnected.
Avoid loads with high starting current like high-power water pumps in the PV system.
Otherwise, the o-grid output may fail due to excessive instantaneous power.
Do not start the BACK-UP function if the PV system is not congured with batteries.
Otherwise, the manufacturer shall not be liable for related system risks.
Factors such as: temperature, humidity, weather, etc. may limit the battery's current and
aect its loading capacity.
The inverter supports UPS, and the switching time of UPS is less than 10ms. The UPS
function may fail to start if the BACK-UP load capacity exceeds the rated power of the
inverter.
When single overload protection occurs, the inverter can restart automatically; however,
the restarting time will be extended if it happens several times. For a faster restarting, try it
via app.
Normal household loads can be supported when the inverter is in back-up mode. Accepted
loads as below:
Inductive loads: 1.5P non-inverter air conditioner
Capacitive loads: total power 0.6 times of the inverter’s rated output power.
For the grid type with neutral wire, the voltage between the neutral wire and the ground must
be less than 10V.
Inverter Inverter Inverter Inverter
L1
L2
L3
N
PE
PE
TN-S
L1
L2
L3
PEN
PE
TN-C
L1
L2
L3
N
PE
PE
TN-C-S
L1
L2
L3
N
PE
TT

Other manuals for Goodwe GW10K-ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe GW10K-ET and is the answer not in the manual?

Goodwe GW10K-ET Specifications

General IconGeneral
ModelGW10K-ET
Max. DC Input Voltage1000 V
Number of MPPTs2
Rated AC Output Power10000 W
Max. AC Output Power11000 VA
Frequency50 Hz / 60 Hz
Efficiency98.3%
Dimensions516 x 415 x 180 mm
Weight25 kg
Max. DC Input Power13000 W
Start Voltage180 V
MPPT Voltage Range200V - 1000V
Number of MPP Trackers2
Max. Short Circuit Current per MPPT15 A
Nominal AC Output Power10000 W
Max. AC Apparent Power11000 VA
Nominal AC Voltage230 V / 400 V
Nominal Grid Frequency50 Hz / 60 Hz
THDi<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Rated Output Power10000 W
Grid Frequency50 Hz / 60 Hz
Max. Efficiency98.3%
Noise Level<30 dB
Protection DegreeIP65
TypeThree Phase
AC Voltage Range180V - 280V
Power Factor0.8 leading - 0.8 lagging
Rated Grid Voltage230 V