02 Safety PrecautionUser Manual V1.1-2022-12-20
2.5 Personnel Requirements
NOTICE
Personnel who install or maintain the equipment must be strictly trained, learn about
safety precautions and correct operations.
Only qualied professionals or trained personnel are allowed to install, operate, maintain,
and replace the equipment or parts.
2.4 Battery Safety
WARNING
The battery used with the inverter shall be approved by the inverter manufacturer. The
approved battery list can be obtained through the ocial website.
Before installations, read through the corresponding battery's User Manual to learn about
the product and the precautions. Strictly follow its requirements.
If the battery discharged completely, please charge it in strict accordance with the
corresponding user manual.
Factors such as: temperature, humidity, weather conditions, etc. may limit the battery's
current and aect its load.
Contact after-sale service immediately if the battery is not able to be started. Otherwise,
the battery might be damaged permanently.
Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the
voltage should be under the permissible range.
Do not connect one battery group to several inverters at the same time. Otherwise, it may
damage the inverter.

Other manuals for Goodwe GW10K-ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe GW10K-ET and is the answer not in the manual?

Goodwe GW10K-ET Specifications

General IconGeneral
ModelGW10K-ET
Max. DC Input Voltage1000 V
Number of MPPTs2
Rated AC Output Power10000 W
Max. AC Output Power11000 VA
Frequency50 Hz / 60 Hz
Efficiency98.3%
Dimensions516 x 415 x 180 mm
Weight25 kg
Max. DC Input Power13000 W
Start Voltage180 V
MPPT Voltage Range200V - 1000V
Number of MPP Trackers2
Max. Short Circuit Current per MPPT15 A
Nominal AC Output Power10000 W
Max. AC Apparent Power11000 VA
Nominal AC Voltage230 V / 400 V
Nominal Grid Frequency50 Hz / 60 Hz
THDi<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Rated Output Power10000 W
Grid Frequency50 Hz / 60 Hz
Max. Efficiency98.3%
Noise Level<30 dB
Protection DegreeIP65
TypeThree Phase
AC Voltage Range180V - 280V
Power Factor0.8 leading - 0.8 lagging
Rated Grid Voltage230 V