Alarms: Firmware Versions 6.02 and Above
70 332305J
Pressure
Warning
System fails to relieve pres-
sure in the user-defined
amount of time.
Unit will continue to oper-
ate for the number of lubri-
cation cycles set by the
warning retry parameter
(see Advanced Program-
ming, page 48).
If the warning condition
clears itself on the next
automatic lubrication cycle,
the warning is cleared and
the unit continues normal
operation.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press the
RESET but-
ton to clear
warning.
Cycle Fault In cycle mode indicates
that a cycle was not com-
pleted in the user-defined
amount of time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press and
hold the
RESET but-
ton to clear
fault.