EasyManua.ls Logo

Graco G3 Series - Pressure Warning; Cycle Fault

Graco G3 Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarms: Firmware Versions 6.02 and Above
70 332305J
Pressure
Warning
System fails to relieve pres-
sure in the user-defined
amount of time.
Unit will continue to oper-
ate for the number of lubri-
cation cycles set by the
warning retry parameter
(see Advanced Program-
ming, page 48).
If the warning condition
clears itself on the next
automatic lubrication cycle,
the warning is cleared and
the unit continues normal
operation.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press the
RESET but-
ton to clear
warning.
Cycle Fault In cycle mode indicates
that a cycle was not com-
pleted in the user-defined
amount of time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press and
hold the
RESET but-
ton to clear
fault.
ON
OFF
!
1 23
HH MM
SS ##
MM : SS HH : MM
2
3
1
P
C
C
P
C
P
C
P
ON
OFF
!
1 23
HH MM
SS ##
MM : SS HH : MM
2
3
1
P
C
C
P
C
P
C
P

Table of Contents