Alarms: Firmware Versions 6.02 and Above
332305J 71
Pressure
Fault
In pressure mode indi-
cates that unit is over pres-
surized or a lubrication
cycle was not completed in
the user-defined amount of
time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press and
hold the
RESET but-
ton to clear
fault.