CS500/IS200-UM-251-9370 8-22
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
Reattaching the data controller board
(1) Reattach the data controller board in the reverse order in which it was detached.
(2) Prepare corresponded the data controller board before replacing the data controller board.
If the model name is CS500-11 or IS200-11 use the data controller board for the CS500-11 or IS200-11.
If the model name is CS500-11-A or IS200-11-A use the data controller board for the CS500-11-A or
IS200-11-A.
(3) Set the DIP switch setting for each model (See "Replacing the Data Controller Board" in Section 9.2).
(4) Perform the software adjustment to input the former setting values or adjust the scanner by software
adjustment. (See "Preparations before Making Adjustments" in Section 10.2)
(5) When replacing the data controller board, write down the MAC address that is shown on the old data
controller board on the new data controller board.
When replacing the data controller board, perform the software adjustment to obtain the former setting values from
data controller board. (See "Preparations before Making Adjustments" in Section 10.2)