10. ADJUSTMENTS USING THE SOFTWARE
2. Feed distance adjustment
(1) Start the software. (See p. 10-1)
(2) Select "Adjust Feed Distance" from the "Adjust" menu.
(3) The following dialog box will appear: Correctly position the 42-inch test chart on the scanner and click
the "Scan" button.
(4) The following dialog box will appear: Click the "Scan" button.
Select the following for "Document Info" and "Scan Settings":
"Document Info" Paper Size: User Size, Width: 1016, Length 1100, Resolution: 600 dpi
Document Type: Black and White
"Scan Settings" Output: Bilevel