CS500/IS200-UM-251-9370 10-5
10. ADJUSTMENTS USING THE SOFTWARE
10.4 Making Adjustments
Always follow the sequence given below when making adjustments.
1. Calibration (white correction)
2. Feed distance adjustment
3. Position adjustment
Offset adjustment
Sensor joint alignment
4. Color correction
Scanner Calibration
Before beginning calibration, clean the scanner glass and scanner table surface. Any dust or dirt on this
surface may affect calibration results and resulting image quality.
Check that the calibration sheet is free of any dust or dirt.
1. Calibration (white correction)
(1) Connect the scanner to the computer. Switch on the scanner, then switch on the PC.
(2) Start Scanning Master 21+. (See p. 10-1.)
(3) Remove the white calibration sheet (220 x 1070 mm) from its special storage box.
Clean the sensor glass surface and the document hold-down unit.
220 mm
1070 mm
Calibration sheet
(4) Select "Calibration" from the "Adjust" menu.