CS500/IS200-UM-251-9370 8-21
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.20 Data Controller Board
When replacing the data controller board, perform the software adjustment to obtain the former setting values from
the data controller board.
Detaching the data controller board
(1) Detach the right and left side covers (see Sections 8.1 and 8.2).
(2) Detach the front guide assembly (see Section 8.4).
(3) Detach the IEEE 1394 board (see Section 8.19).
(4) Remove the two M3L6 flat head screws holding the USB cover and then detach the USB cover from the
unit.
M3L6 Flat head screw
M3L6 Flat head screw
(5) Disconnect all the connectors on the data controller board and remove the two M3L6 binding head
screws, the one M2 spacer and the two M3 spacers holding the data controller board.
M2 Spacer
M3 Spacer
M3L6
binding head
screw
USB cover
(6) Detach the data controller board from the unit.