OCP 400 Operational Control Panel User’s Guide (v12.0) 23
Chapter 3 - Setup
3.3.3 IP and Ethernet configuration
For the OCP to operate in a network environment it must have a unique identification. By
default, an IP address is assigned automatically. To set the IP address manually use the IP
CONFIG and ETH CONFIG submenus.
Menu Selections Function Level Possible values
IP Config
page 1
IP Mode IP address assignment F Auto, Manual
Apply Sets IP mode F Press button to activate the new
IP settings
Subnet Mask Subnet mask address F 255.255.0.0
—
IP Config
page 2
IP Byte 1 IP address 1st byte F 1..250 (192)
IP Byte 2 IP address 2nd byte F 0..255 (168)
IP Byte 3 IP address 3rd byte F 0..255 (0)
IP Byte 4 IP address 4th byte F 1..254 (2)
Menu Selections Function Level Possible values
Ethernet
Config
page 1
Eth Speed Ethernet speed setting F 10 Mbit, 100 Mbit, Auto
Duplex Ethernet duplex-mode setting F Full, Half, Auto
—
—