EasyManua.ls Logo

GRASS VALLEY OCP 400 - Variable Matrix and Shading

GRASS VALLEY OCP 400
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28 OCP 400 Operational Control Panel User’s Guide (v12.0)
Chapter 3 - Setup
3.5.1 Variable matrix and shading
The Variable Matrix and Shading menus are submenus of the camera setup menu.
Menu Selections Function Level Possible values
Variable
Matrix
page 1
G->R Sets the green to red ratio. F 0..99 (50)
B->R Sets the blue to red ratio. F 0..99 (50)
R->G Sets the red to green ratio. F 0..99 (50)
B->G Sets the blue to green ratio. F 0..99 (50)
Variable
Matrix
page 2
R->B Sets the red to green ratio. F 0..99 (50)
G->B Sets the green to blue ratio. F 0..99 (50)
-
-
Menu Selections Function Level Possible values
Shading
page 1
Shading Turns shading on or off F On, Off
-
-
-
Shading
page 2
R-SAW H Sets the horizontal sawtooth
value (for red)
F 0..99 (50)
R-PAR H Sets the horizontal parameter
(for red)
F 0..99 (50)
R-SAW V Sets the vertical sawtooth value
(for red)
F 0..99 (50)
R-PAR V Sets the vertical parameter (for
red)
F 0..99 (50)
Shading
page 3
G-SAW H Sets the horizontal sawtooth
value (for green)
F 0..99 (50)
G-PAR H Sets the horizontal parameter
(vor green)
F 0..99 (50)
G-SAW V Sets the vertical sawtooth value
(for green)
F 0..99 (50)
G-PAR V Sets the vertical parameter (vor
green)
F 0..99 (50)
Shading
page 4
B-SAW H Sets the horizontal sawtooth
value (for blue)
F 0..99 (50)
B-PAR H Sets the horizontal parameter
(for blue)
F 0..99 (50)
B-SAW V Sets the vertical sawtooth value
(for blue)
F 0..99 (50)
B-PAR V Sets the vertical parameter (for
blue)
F 0..99 (50)

Table of Contents