OCP 400 Operational Control Panel User’s Guide (v12.0) 51
Chapter 4 - Operation
Detail Equalizer
Camera systems that have parallel SD outputs, detail parameters have different values for the
High Definition (HD) output and the Standard Definition (SD) output. Press the NEXT button to
open the second (SD output) set of parameters.
4.5.12 Non-standard indication
Normally if the menu of a function group is active, the button is illuminated high green. But in
the case that the function group is non-standard ánd the menu is active, the button will be
illuminated yellow (mix of orange and high-green).
When a button is illuminated as non-standard, it is possible to see which individual function or
functions is/are nonstandard. This is indicated with a *-symbol behind every non-standard
value in the menu.
Menu Selections Function Level Possible values
SD detail
page 1
SD DTL LVL Detail Level S SD 0..99
SD DTL Funct Detail Function S SD On, SD Off
SD LVL Dep Level Dependency B SD 0..99
SD NoiseSL NoiseSlicer B SD 0..99
SD detail
page 2
SD V Detail Vertical detail level B SD 0..99
SD C/Fine Detail fine adjustment B SD 0..99
-
-
SD detail
page 3
-
SD SOFT LVL Soft detail level B SD 0..99
SD Soft DTL Soft detail function B SD On, SD Off
SD Sourc Detail source Selection B SD Y,SD R,SD G,SD R+G
Menu Selections Function Level Possible values
SD detail
page 1
SD DTL LVL Detail Level S SD 0..99
SD DTL Funct Detail Function S SD On, SD Off
SD LVL Dep Level Dependency B SD 0..99
SD NoiseSL NoiseSlicer B SD 0..99
SD detail
page 2
SD V Detail Vertical detail level B SD 0..99
SD C/Fine Detail fine adjustment B SD 0..99
-
-
SD detail
page 3
-
SD SOFT LVL Soft detail level B SD 0..99
SD Soft DTL Soft detail function B SD On, SD Off
SD Sourc Detail source Selection B SD Y,SD R,SD G,SD R+G