46 OCP 400 Operational Control Panel User’s Guide (v12.0)
Chapter 4 - Operation
Color Corrector Menu
4.5.6 Black button
– Press the BLACK button to open the black menu.
– The lower row of rotary controls are assigned to changing the black values. The BLACK
light lights.
4.5.7 Flare button
– Press the FLARE button to open the flare menu.
– The lower row of rotary controls are assigned to changing the flare values. The FLARE
lights light.
Menu Selections Function Level Possible values
Color
corection
page 1
CC SET: n Selects color correction set S 1..6 (1,2)
On/Off Turns color corr. set on or off S On, Off
Color Sets Color S 0 . .360°
Width Sets Color Width S 22.5 .. 360°
Hue Sets new Hue value for the
selected color
S 0..99
Sat Sets new Saturation value for
the selected color
S 0..99
Lum Sets new Luminance value for
the selected color
S 0..99
Color
corection
page 2
CC View Views color area S On,Off
ViewInsert CC View insertion point S Main, Mon
Smoothing Selexts transition between
corrected and uncorrected area
S Sharp, Medium, Smooth
Reset CC Resets all color correction sets S (execute)
Menu Selections Function Level Possible values
Black
page 1
Black Str Black Stretch Function S On,Off
Auto Black Auto Black Function S <Press to start>
BlkStrLvl Black Stretch Level S 0..99
BlkStrTyp Black Stretch type B Press, Stretch
Black
page 2
—
FullBlack Runs Full Black calibration B On, Off
—
—