OCP 400 Operational Control Panel User’s Guide (v12.0) 47
Chapter 4 - Operation
4.5.8 Exposure time button
– Press the EXP.TIME button to open the exposure time menu.
4.5.9 Gain button
– Press the GAIN button to open the gain menu.
– Select GAIN+ or GAIN- to increase or decrease the gain in steps.
4.5.10 Filters button
– Press the FILTERS button to open the filters menu.
Menu Selections Function Level Possible values
Flare Flare FUNC Flare function F On, Off
Flare R Red Flare Level S 0..99
Flare G Green Flare Level S 0..99
Flare B Blue Flare Level S 0..99
Menu Selections Function Level Possible values
Exposure
time page 1
Exp. Sel Selects exposure time S Nom, CRT, 50, 60, 1/100..1/2000,
Var
Lighting Switches Lighting adj. on or off S On, Off
Var Exp Sets variable exposure time S xx Hz or xx mSec
Lighting Sets lighting adjustment value S -10..+10
Exposure
time page 1
[VIPER ]
Shutter Selects shutter preset (Viper
only)
S 90, 180, 216, VAR, MAX etc.
Angle Sets variable shutter angle
(Viper only)
S 90° .. 315°
Motor Turns shutter motor on or off
(Viper only)
SOn, Off
-
Exposure
time page 2
AutoLight Auto Lighting function S On, Off
-
Exp Unit Exposure Time Unit (for Var) S On, Off
-
Menu Selections Function Level Possible values
Gain GAIN + Increases gain S +++, ++, +, 0, -
VAR MGain Sets variable Master Gain S x, xdB
GAIN - Decreases gain S -, 0, +, ++, +++
StudioMode S On, Off