EasyManua.ls Logo

Grecom PSR-310 - Page 66

Grecom PSR-310
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
*48*** (To enter the code, 048000: This scanner does not input the * in this
entering. Use 0 instead of *.)
This tells the radio to alert on any SAME message with a location code that
matches 48 for the state of Texas.
Your scanner also allows you to specify the event code. The default alert
code is ā€œ***ā€, which is best for most general purpose weather alert monitor-
ing purposes. A list of event codes can be found at this web site:
http://www.weather.gov/os/eas_codes.shtml
Each SAME location/event code storage location can be configured for En-
try ON/OFF and Lockout ON/OFF.
When a SAME location/event code storage location is set for Entry ON, the
radio will process the SAME location/event code that is stored there. When
a SAME location/event code storage location is set for Entry OFF, that SAME
location and event code will be ignored.
When a SAME location/event code storage location is set for Entry ON and
Lockout ON, the radio will process the SAME location/event code that is
stored there, and will lock out the specified event code. A SAME location/
event code storage location set for Entry: OFF and Lockout: ON will not be
processed, because Entry is set to OFF. In case of a conflict (i.e., two identi-
cal codes and events are entered, and one is locked out), the locked out
entry will take precedence.
SAME Entry Examples
Using the Dallas County, TX example above:
SAME Entry 1:
Code: 048113
Event: ***
Entry: ON
Lockout: OFF
SAME Entries 2-10:
Code: ******
Event: ***
Entry: OFF
Lockout: OFF
The above entry for 048113 will receive all SAME messages for 048113.
SAME Entry 1:
Code: 048113
Event: ***
Entry: ON
Lockout: OFF

Table of Contents