AC ERROR LISTING
AC Error 1 listing (HEX field):
Error Name
HEX
Code
DEC
Code
AC response Reason Remedy Note
No error 0x0000 0 / / /
IG part lost
0x0001 01
Permanent
error mode
CAN communication
with IG part interrupted
Check / replace
HCU
1
Actuator
fail
0x0002 02
Permanent
error mode
Clutch signals have the same
logic state for more than 6 s
Check clutch signals
Cont. high
ph. current
0x0004 03
Permanent power
reduction
Phase current continuously
above max level
Stop / Check load 3
Cont. high
bat. current
0x0008 04
Permanent power
reduction
Calculated battery current
continuously above max level
Stop / Check load 3
Hall failure
0x0010 05 Error mode Hall sensor malfunction
Check / replace hall
sensors assembly
Motor
temp. max
0x0020 06 Error mode
Measured motor temperature
above 120°C
cooling required
HCU
temp. max
0x0040 07 Error mode
HCU temperature
above 95°C
Stop, HCU cooling
required
Battery
voltage
max
0x0080 08 Error mode
Battery voltage
above 58 V
Check battery
DC_link
over
voltage
0x0100 09 Error mode
DC-link voltage
above 270 V
Wait for DC-link
voltage drop
4
Invalid HCU
command
0x0200 10 Error mode
Wrong state of HCU
command inputs
Check HCU
inputs wiring
Battery
temp. max
0x0400 11 Error mode
Battery temperature
above 55°C
Check battery and
temp. sensor
5
Motor
0x0800 12 Error mode
Measured motor temperature
Check / replace hall
sensors assembly