Greenline 40
65
The AC error code 0x0004 indicates a full battery. This is not an error; it only means the generator won't
charge the battery. You may drive either in electric or diesel mode.
The AC1 error code 0x0002 indicates that the clutch did not disconnect from the diesel engine in time. Try to
restart the HCU unit by resetting (switch diesel engine keys to OFF position for 10 sec).
If the HCU is in »error mode« (ERR), first try to restart the HCU unit by resetting (switch diesel engine keys to
OFF position for 10 sec).
For other errors please refer to the error list in Appendix B. For detailed information read the Data display
interface (DDI) instruction manual.
BATTERY MONITORING - BMV
The battery monitor shows important data about the main 48V LiPo battery bank and about the 12V service
battery.
Standard information and alarms:
- Battery voltage of LiPo battery (full battery @ 54.3V).
- Battery voltage of service battery (full battery @ 14.4V).
- Battery charge/discharge current (A): - consumption, + charging
- Ampere-hours consumed (Ah).
Screen 3 – no LED (only in diesel mode / generator)
Charging phase Battery temp.
Charging level Final chg. Level/abs. Time
Charging ph. Duration Total charging duration