Greenline 40
66
- Battery status (%).
- Time to go (time to empty) at the current rate of discharge (see Victron owner`s manual).
- Visual and audible alarm: over and under voltage. (During an alarm the buzzer will sound. The alarm buzzer
can be silenced by pressing any button.)
For switching between the data screens press »+« or »-«. For detailed information and changing the settings,
please read the manufacturer's owner's manual.
CAUTION!
If the battery voltage drops under 44V, the alarm will turn ON (it will
turn OFF after voltage rises above 46V) – turn off all consumers (incl.
propulsion) and recharge the battery.
CAUTION!
If the battery voltage rises above 54.7V, the alarm will turn ON (it will
turn OFF after voltage drops under 54.4V) – turn off the power sources
(generator, shore cable) and discharge the battery (with propulsion or
consumers through the inverter).
If the over voltage alarm turns on frequently, please report the error
to your local dealer.
CAUTION!
Never discharge the LiPo battery under 43V!
Do not change or tamper with the charging system!
Never overcharge the LiPo battery above 54.5V!
PHOENIX MULTI CONTROL INVERTER / CHARGER
Phoenix multi control (Pic. 05) is the main control panel regarding the 48Vdc / 230Vac inverter/charger.
You can choose between ON (charger ON, 230V output ON from shore or from inverter) and CHARGER ONLY
(charger ON, 230V output only when shore cable is plugged).