GREER Company
1918 East Glenwood Place
Santa Ana CA 92705
Page 34 of 44
MicroGuard
®
586 Operation/Setup Manual
W458200 REV C 10/29/02
OK
DISPLAY
SETUP
STOP
RATED CAPACITY
MG-586
!
SELECT
CONTRAST
Entering Setup Mode
The display will step through each setup operation, as required by the user. During the setup procedure, the
display console should be placed in a position that allows easy viewing while adjustments are being made within
the boom extension reel, and allows for operation of the display buttons.
The setup mode is activated by the following procedure:
1. Make sure machine power is OFF.
2. Turn ON machine power.
3. During self-test, check that the correct machine
model and capacity chart number is displayed
on the console.
4. Hold down "Setup" and "up arrow" on the
display for 5 seconds at any time to start the
self-test.
5. Release the buttons.
6. If the display does not indicate SETUP in the
SETUP CODE window, check that the System is in
the NORMAL-working mode (NOT the
configuration mode) with no error codes.
OK
DISPLAY
SETUP
SETUP CODE
STOP
RATED CAPACITY
MG-586
!
SELECT
CONTRAST
OK
DISPLAY
SETUP
SETUP CODE
STOP
RATED CAPACITY
MG-586
!
SELECT
CONTRAST
Setup Mode
Entry