Baserunner V6 User Manual
Rev0
12 Specifications
12.1.1 Electrical
Peak Battery Current Programmable up to 80A (L10) or 55A (Z9)*
Phase A limits practical value to ~40A (L10) 25A (Z9)
Peak Phase Current Programmable up to 80A (L10) or 55A (Z9)*
Peak Regen Phase Current Programmable up to 80A (L10) or 55A (Z9)*
Continuous Phase Current Approximately 50A (L10), 30A (Z9) at thermal
rollback, varies with air flow and heat sinking
Phase Current Rollback Temp 90°C Internal Temp (casing ~70°C)
Max Battery Voltage 60V (14s Lithium, 17s LiFePO4)
Min Battery Voltage 19V (6s Lithium, 7s LiFePO4)
eRPM Limit Not recommended above 60,000 eRPM, though it
will continue to function beyond this.
Max Batt+ Current for Lights
on Main9 or CA3 Plugs
750 mA (limited by self resetting polyfuse)
RShunt for Cycle Analyst 1.00 mΩ
*Thermal rollback will typically kick in after 1 to 2 minutes of peak phase current, and then phase
current will automatically reduce to maintain controller rollback temperature.
12.1.2 Mechanical
Dimensions LxWxH 104 / 99 x 55 x 15.5 mm (L10 / Z9)
Weight 0.25 / 0.20kg (L10 / Z9)
Signal Cable Length 15cm to Connector End
Motor Cable Length 38cm to Connector End
Waterproofing Fully Potted Circuitry, IP rated signal plugs