(Revised 1/02)
TROUBLESHOOTING
7-17
PROBLEM: WATER LEAKS
Probable Cause
Corrective Action
Leaks around water inlet valve.
Cracked water inlet valve housing.
Leaks around heating elements and
boiler water inlet fittings.
WARNING
Be sure oven is disconnected from branch cir-
cuit power before performing any repair work.
Replace garden hose gasket. See page 8-25.
Tighten hose clamp, but do not overtighten.
Replace a damaged hose.
Replace valve. See page 8-27.
Tighten mounting nuts.
Replace fiber washers. See page 8-49.
PROBLEM: IMPROPER CONDENSATE SPRAY OPERATION
Probable Cause
Corrective Action
Conditions required to turn on spray:
Steam Mode - Door closed, and timer operating or boiler water ready and drain hot.
Combo Mode - Door closed and boiler water at ready temperature.
WARNING
When oven power is turned on, there is high
voltage present in the electrical components
compartment.
Test water inlet valve. See page 8-6.
24V
AC measured.
Inspect spray nozzle for blockage. If
necessary, clean nozzle.
24VAC not measured. Measure voltage between K14
contacts.
No condensate spray.