26 of 36© 2009 D 664 - 07/09
664 Monitor Menu (1 of 2)
Outdoor High The highest recorded outdoor air temperature
since this item was last cleared.
-85 to 170°F
(-65 to 77°C)
Outdoor Low The lowest recorded outdoor air temperature
since this item was last cleared.
-85 to 170°F
(-65 to 77°C)
Slab 1 High The highest recorded temperature at the slab
sensor of zone 1 since this item was last cleared.
Zone 1 = Auto
-85 to 170°F
(-65 to 77°C)
Slab 1 Low The lowest recorded temperature at the slab
sensor of zone 1 since this item was last cleared.
Zone 1 = Auto
-85 to 170°F
(-65 to 77°C)
Slab 2 High The highest recorded temperature at the slab
sensor of zone 2 since this item was last cleared.
Zone 2 = Auto
-85 to 170°F
(-65 to 77°C)
Slab 2 Low The lowest recorded temperature at the slab
sensor of zone 2 since this item was last cleared.
Zone 2 = Auto
-85 to 170°F
(-65 to 77°C)
Mix High The highest recorded temperature at the mixing
supply sensor since this item was last cleared.
-25 to 230°F
(-32 to 110°C)
Mix Low The lowest recorded temperature at the mixing supply
sensor since this item was last cleared.
-25 to 230°F
(-32 to 110°C)
Zone 1 Pump or Valve The total number of zone 1 pump or
valve running hours since this item was last cleared.
Zone 1 = Auto
0 to 9999 hr
Zone 2 Pump or Valve The total number of zone 2 pump or
valve running hours since this item was last cleared.
Zone 2 = Auto
0 to 9999 hr
System Pump The total number of system pump (Sys P1)
running hours since this item was last cleared.
0 to 9999 hr
Item Field Description
Range
Access
Level
LTD
USER
INST
ADV
Note: To clear the recorded information in the specific item field, press and hold ▲ and ▼.