58
PQ configuration example on WX5002
Table 10 describes the Ethernet interface configuration prerequisites on different WX
series access controllers.
Table 10 Ethernet interface configuration prerequisites
Ethernet interface configuration prerequisites
Switches
installed
with
access
controller
modules
Access
controller
modules
LS8M1WCMA0
LSQM1WCMB0
LSBM1WCM2A0
LSRM1WCM2A1
No special requirements. You can directly
configure Ethernet interfaces on the switch.
To configure wireless features during the
configuration process, log in to the access
controller module with the oap connect slot
slot-number command.
No special requirements. You can directly
configure Ethernet interfaces on the switch.
To configure wireless features during the
configuration process, log in to the access
controller module with the mcms connect [ slot
slot-number ] system system-name command.
Use the oap connect slot 0 command on the
access controller engine to log in to the
switching engine.
Use the oap connect slot 0 command on the
active main control board to log in to the switch
interface board.
No special requirements. You can directly
configure a GE interface on the access
controller.
Network requirements
As shown in Figure 14 , Client A and Client B get data from Server through the AC.
Configure the AC to preferentially process data from the higher-priority client.