Chapter 3
Operation
30
Copyright © 2010, Harris Corporation
Alarms are usually logged and monitored within the available software control
applications. See the appropriate software control user manual or online help for
more information.
Table 3-3 Alarm Definitions
Alarm Name Alarm Description Alarm Level
Ch. 1 loss of input Indicates input signal for channel 1 is lost
or absent
Major
Ch. 2 loss of input Indicates input signal for channel 2 is lost
or absent
Major
Ch. 1 loss of lock Indicates signal for channel 1 is not
locked
Major
Ch. 2 loss of lock Indicates signal for channel 2 is not
locked
Major
Ch.1a Tx Fault Indicates SFP transmitter fault on
channel 1a
Major
Ch.1b Tx Fault Indicates SFP transmitter fault on
channel 1b
Major
Ch.2a Tx Fault Indicates SFP transmitter fault on
channel 2a
Major
Ch.2b Tx Fault Indicates SFP transmitter fault on
channel 2b
Major