NUCLEUS Installation and Operation Manual 35
Chapter 3: Specifications
Power Consumption
Replacing Fuses
To access the power supply fuse, follow these steps:
1. Remove the AC power cord from the back of the control panel.
2. Locate the fuse access cover above the AC power cord inlet, and
then squeeze both ends of the cover to remove it.
3. Remove the fuse, and then replace it with another 1.6 A 250 V
20 mm cartridge fuse.
For continued protection against risk of fire, replace only with the
same type 1.6 A 250 V 20 mm fuse.
To avoid the risk of fire, you must always replace the fuse with the
same type of fuse and specified rating. Failure to comply may result
in result in personal injury and/or equipment damage.
4. Re-install the fuse cover.
5. Re-connect the AC power supply.
Serial RS-232/422 serial port
USB USB type A receptacle
PS/2 Mini Din 6-pin female
Table 3-3. Connection Specifications (Continued)
Item Specification
Table 3-4. Power Consumption Specifications
Item Specification
Power consumption Input power: 10.0 W max. at 100 to
240 VAC, 50/60 Hz
Input fuse
1.6A - 250 VAC
Fuse type and marking: T1.6 AH 250 V