146 4000662720 E 06.17 USA / EN
E
- Adjustments
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
FAILURES N DEC DESCRIPTION
CAN J1939
F15.06
Check CAN2
-
D
Problem detected in J1939 CAN
• Machine not supplied, with multimeter, check the resistance between 2001 (CAN high) and
2002 (CAN low) is nearly 60 ohms (if 0 ohm or 120 ohm : failure, check RES TERM
connection for all ECUs)
• Check ECU supplies line
• Check CAN connection for Display and/or engine