31 / 34
Pre-selection of Trolley or Hoist
The operator is able to select the trolley or hoist that he wishes to control. It is also possible to
simultaneously control both trolleys/hoists, for example in order to transport particularly long or wide loads.
Cable Control
With a cable you can generate a direct data connection between
the transmitter and receiver. The radio transmission is disabled.
At the same time, the power supply of the transmitter is provided
through the cable, as well.
Connecting the cable
1. Switch the transmitter off.
2. Remove the screw lock on the transmitter and receiver.
3. Connect the transmitter and the receiver with the cable.
Ensure that the connector is locked.
4. Switch the transmitter on.
Notes:
x
If you connect the cable while working with the system, the
transmitter will switch off
automatically.
Activate the transmitter as describe in the chapter “Operation” to switch to cable
operation.
x When the system is in cable mode the transmitter will receive the supply voltage from the
receiver, i.e. the transmitter can be used without the battery.
x If you disconnect the cable from the transmitter and receiver, the system will switch off
automatically.
Activate the transmitter as describe in the chapter “Operation” to switch to radio
operation.
radiomatic
®
CPS
With radiomatic
®
CPS (= Continuous Power Supply), the battery of the radio control can be changed
without interrupting power. For this, the transmitter has an additional, built-in battery.
This function is ideal if long and interruption-free crane or machine operations are required.
The current operating status is shown in the display’s status bar:
Indication
Meaning
The internal battery is operational.
The transmitter is operated with the external battery.
The transmitter is operated with the internal battery.
The external battery is empty or not inserted.
After 25 minutes an acoustic signal sounds and the transmitter vibrates. After 30 minutes
the transmitter will switch off.
The internal battery is charged.
The transmitter is operated with the external battery.
The transmitter is operated with the external battery.
Operation with the internal battery is not possible. The battery is empty or defect.
illuminates
blinks