53
PME-MP55
HBMA0563-5.6 en
7.6 Manufacturer-specific objects in FLOAT data format
Index
(hex)
Sub-
index
Name Format Attr. Values
Measured values:
3000 1 Gross value float ro
3001 1 Net value float ro
3002 1 Maximum float ro
3003 1 Minimum float ro
3004 1 Peak-to-peak float ro
3005 1 Value in mV/V float ro
3006 1 Analogue output value float ro
Transducers
3140 1 Transducer null mV/V float rw Value in mV/V
3141 1 Transducer null physical unit float rw Value e.g. in
kN
3142 1 Transducer sensitivity mV/V float rw Value in mV/V
3143 1 Transducer nominal value physical unit float rw Value e.g. in
kN
3150 1 Input characteristics at 1st point mVV float rw
3151 1 Input characteristics at 2nd point mVV float rw
3160 1 Input characteristics at 1st point in
phys. unit
float rw
3161 1 Input characteristics at 2nd point in
phys. unit
float rw
Conditioning
3180 1 Tare value float rw
3181 1 Zero balance value float rw
3185 1 Zero reference float rw
31A1 1 Standstill monitoring by amplitude float rw
Analogue output
31D0 1 Zero point of analogue output phys. unit float rw
31D1 1 Final value of analogue output phys.
unit
float rw
31D2 1 Zero point of analogue output V float rw
31D3 1 Final value of analogue output V float rw