1 Introduction
The digital adjustable charge amplifier CMD600 has an Ethernet interface for
configuration and digital datastreaming and a realtime signal output as
" 10VDC voltag output.
On powerup is output voltage 10V and both digital outputs are on logical
state 0. The power-up time is 300 ms.
2 Network settings
Each unconfigured amplifier comes from production with preset unique
Ethernet address and factory default settings. Default IP address is
192.168.1.10 and netmask 255.255.0.0. DHCP is enabled by default.
If there is no DHCP server on the network it can happened that development
computer is not necessary on the same subnet as amplifier (IP address
different from 192.168.1.X). If this is true there should be taken care about
this. For this purpose IP address on development computer should be set as
on Figure Fig. 1.
When the connection to amplifier is established IP address can be changed to
suit desired subnet. If DHCP is enabled IP settings of amplifier are set
automatically.
Fig. 1: Development computer IP settings