EasyManua.ls Logo

HBM PACEline CMD600 - Data_Stream_Rate; Data_Stream_Target; Device_Name

HBM PACEline CMD600
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
CMD600
A28201.1 en
Num-
ber
Protect-
ion
Glo-
bal
Default value Description
27 N N 0 Limit switch 1 threshold [EnUn]
28 N N 0 Limit switch 1 polarity.
0..active if output
1 > threshold 1.. active if output 1 <
threshold
29 N N 0 Limit switch 1 hysteresis [EnUn]
30 N N 0 Limit switch 2 threshold [EnUn]
31 N N 0 Limit switch 2 polarity.
0..active if output 2 > threshold
1.. active if output 2 < threshold
Limit switch 2 hysteresis [EnUn]
32 N N 0 Limit switch 2 hysteresis [EnUn]
33 N N 1.0000E+00 Data stream rate [Hz] (min = 1, max =
1000)
34 N N 2 DHCP mode(1..disable, 2..enable)
35 N N 192.168.1.1 IP address
36 N N 23 Telnet port
37 N N 255.255.0.0 Subnet mode
38 N N 192.168.1.0 IP gateway
39 Y Y 00:04:0E:F8:09:F6 Ethernet address (MAC)
40 N N 0.0.0.0 Data stream target
41 N N 12345 UDP port
42 N N 1 Auto scale allow (0..disable,1..enable)
43 N N 1.0000E+00 Overload reserve [V]
44 Y Y HBM Manufacturer
45 Y Y CMD600 Device type
46 Y Y 0000 Serial number
47 N N New amplifier Nb 0000 Device name
48 N N 60000 Connection timeout in ms
49 Y Y 20 Input offset slow HPF
50 Y Y 300 Input offset fast HPF
51 Y Y 5.0000e4 HPF and LPF on k koef
52 Y Y 1.1538e1 HPF and LPF on n koef
53 N N 0 Reset compensation disable
(0..compensation enabled,
1..comp.disabled)
54 N N 0 Reset polarity
(0..logica high level on Reset pin(on
system connector) is reset,
1...logical low on Reset pin is reset)
55 N Y 0 Address of packet of parameters.

Related product manuals