31
CMD600
A28201.1 en
CONNECTION_TIMEOUT
If no communication with amplifier is connection abort after timeout. If setting is changed
new value is active after power cycling.
command CONNECTION_TIMEOUT timeout
parameters:
timeout int requested timeout in seconds
response OK, CONNECTION_TIMEOUT = timeout
parameters:
timeout int timeout in seconds
inquiry CONNECTION_TIMEOUT = ?
response OK, CONNECTION_TIMEOUT = timeout in seconds
help CONNECTION_TIMEOUT?
response OK, CONNECTION_TIMEOUT timeout in seconds
The maximum timeout can be adjusted to 524287 sec = 145 h = 6 days.
ETHERNET_ADDRESS
Set MAC address. This address isn’t changed when factory default is carried out.
command ETHERNET_ADDRESS ethernet_address
parameters:
ethernet_address string Format “XX:XX:XX:XX:XX:XX”
response OK, ETHERNET _ADDRESS = ethernet _address
parameters:
ethernet_address string See description above.
inquiry ETHERNET _ADDRESS = ?
response OK, ETHERNET_ADDRESS = ethernet _address
parameters:
ethernet_address string See description above.
help IP_ADDRESS?
response OK, ETHERNET _ADDRESS ethernet _ address