5.6. Directive for function values
EXPLANATION
For each function, values can be set if you are authorized as the owner. In order
to understand the impact of the set value the table below explains the
consequences of giving a low or high value for each function
FUNCTION
RANGE
CONDITIONS
Vacuum
2-700 mbar
Rule of thumb: the higher the vacuum, the less oxygen
remains in the package, so the product has a longer shelf
life. There are exceptions to this rule
Average vacuum time is 30 - 45 seconds (depending on
the volume of the product)
Seal time
0,1-4,0 sec
This is the time in which the seal wire and/or cutting wire
is heated. The longer the time, the more heat is being
transferred to the bag
Average seal time is 1.8 - 2.5 seconds
Cleaning of the pump
15 minutes
There are no settings possible (See 6.3)