USER MANUAL
39
Jumbo Version: JUM-EN-UL-0 23-03-15
7. TROUBLESHOOTING
The tables below show the possible interference with the corresponding cause and action to be taken
MALFUNCTION
ACTIVITY
SECTION
Control panel does not illuminate
Connect the machine to the power supply
2.4
The control panel is on but there is no
activity after closing the lid
Check / adjust the micro switch of the lid
Please contact
your supplier
Insufficient final vacuum
Check the vacuum settings of the program and
adjust them
Make sure that the extraction opening is not
covered
Check the oil level in the pump
Check / replace the exhaust filter
Check / replace the lid gasket
5.5
2.3
6.5
6.8
Vacuum process is slow
Make sure that the extraction opening is not
covered
Check the oil level in the pump
Check/ replace the exhaust filter
2.3
6.5
Vacuum bag is not sealed correctly
Check the seal program settings and adjust
them
Check / replace the Teflon tape and sealing
wires
Check / replace silicones in the silicon holders
Check the inside of the vacuum for
contamination and clean it
5.5
6.6
6.7
The lid does not open automatically
Check the gas springs
Please contact
your supplier
Error messages for SPDC
F1 in display
Check / adjust the micro switch of the lid
Make sure that the pump is running correctly
Please contact
your supplier
--- in display
Check if the lid is opened correctly