8.Commissioning
8.1 Operating conditions
The following requirements must be fulfilled for smooth device operation.
1. The operating temperature must be within the scope of the values
specified in the technical data.
2. The device must be connected to the
power supply (provide PoE is not used).
3. An antenna must be properly connected to the reading device.
4. A transponder must be within the reading and writing ranges of
the connected antenna.
5. For normal operation, deactivate test mode after
installation. (All DIP switches off).
8.2 The serial interface parameters
The following settings of the serial interfaces are set on delivery. The baud rate
can be changed in the SECS protocol with the parameter 0x01. If you want to
change the baud rate in the ASCII protocol, then please contact the manufacturer
HERMOS.
Signal
Baudrate
19200
Datenbits
8
Stoppbits
1
Parität
ASCII: Even
SECS/HSMS: None