10.7 Error Codes
Automatic reading is
not possible
Reader is still busy with a
former read or write request
Wait until the previous request has
ended.
Execution failed, read
or write operation
cannot be carried out
Reader is still busy with a
former read or write request.
Wait until the previous request has
ended.
Data transfer to the tag
is not possible.
Reader is still busy with a
former read or write request.
Wait until the previous request has
ended.
No transponder or
antenna installed
Antenna is not connected
properly
No readable transponder
within the reading range
Put the transponder in the antenna
area. Check the type and function of
the transponder
Antenna / transponder are
misaligned
Check the alignment of the antenna
and the transponder
Antenna is damaged or too
close to metal
Replace the antenna, check the
tuning
Interference field at
transmission frequency
Check antenna environment for
possible sources of interference.
(Monitors, servomotors…)
Invalid parameter or
data
Check command syntax and data
content
Parameter is not
implemented or out of range
Check parameter syntax and value
The device is not
configured
Check message syntax, check
parameter F „Reader address
Check the baud rate of the serial
interface (Com port)
Transmission error at
serial communication
Check RS232 cable and connector,
Check sources of interference with RS232
Serial communication is
interrupted
Check RS232 cable and connector,
Check sources of interference with
RS232
Ethernet communication is
interrupted
Check Ethernet cable and connector,
check IP address settings
Double or wrong
acknowledgment
Check communication settings at the
host
Locked page cannot
be written
Check the page number to be written,
exchange the tag for the new one