1. Model check and handling
1-27
8) Direction of installation
- Motor can be installed horizontally or at the top or bottom of the shaft.
- Keep the motor cable downward.
- If the motor is installed vertically, install a cable trap so that oils or water do not flow into
the motor.
-
9) Cable disconnection
- Take caution not to stress or damage to the cables.
- If the motor is used as a mobile motor, use flexible cables.
1.6. Handling
1.6.1. Handling precaution
: Mishandling can lead to unexpected accidents or damage. The key items are listed as
follows. Reference the related details and use the drive correctly.
1) Handling
- Do not apply any pressure to the encoder which is the motor detector.
Hitting the shaft with a hammer or falling can cause damages.
- Do not directly connect commercial power (AC220V) to the motor. Over-current can
reduce the magnetic efficiency of the motor. Always connect to the defined servo drive
for operation.