45
Figure 5-3 DPC Interface
Press M key to switch the moving axis: X-axis and Y-axis.
In the adjustment of X Axis, press + key and - key to adjust the position of the cursor in X-direction.
In the adjustment of Y Axis, press + key and - key to adjust the position of the cursor in Y-direction.
When the center of the cursor coincides with the dead pixel, press C key to correct the dead pixel.
Press + key and - key at the same time to delete the dead pixel, refer to 3.8.8 DPC.
Hold C key to exit the current menu and return to the main menu.