9.3.1 Controlling the Signal Contact
With this mode you can remotely control every signal contact individually.
Application options:
X Simulation of an error as an input for process control monitoring
equipment.
X Remote control of a device via SNMP, such as switching on a camera.
9.3.2 Monitoring the Device Status via the Signal
Contact
The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state (see on page 181 “Monitoring the Device Status“)
via the signal contact.
Select the Diagnostics:Signal Contact 1/2) dialog.
In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.
Select "Opened" in the "Manual setting" frame to open the contact.
Select "Closed" in the "Manual setting" frame to close the contact.
enable Switch to the Privileged EXEC mode.
configure Switch to the Configuration mode.
signal-contact 1 mode manual Select the manual setting mode for signal contact
1.
signal-contact 1 state open Open signal contact 1.
signal-contact 1 state closed Close signal contact 1.

Table of Contents

Other manuals for Hirschmann MACH 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 100 and is the answer not in the manual?

Hirschmann MACH 100 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 100
CategorySwitch
LanguageEnglish

Related product manuals