EasyManuals Logo

Hirschmann MACH1000 Series User Manual

Hirschmann MACH1000 Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
Installation MACH1000
Release
06
03/2021
The cross-section of the protective conductor is the same size as
or bigger than the cross-section of the power supply cables.
The cables used are permitted for the temperature range of the
application case.
Relevant for North America:
For use in Class 2 circuits, the copper wire conforms to class 1,
140/167 °F or 167 °F (60/75 °C or 75 °C).
Start connecting the electrical wires only if all the above safety
requirements are fulfilled.
Verify that the electrical installation meets locally or nationally
applicable safety regulations.
Use undamaged parts.
Internal fuses are triggered only in the case of a detected error in the
device. In case of damage or malfunction of the device, turn off the
supply voltage and return the device to the plant for inspection.
Only switch on the device when the housing is closed.
First connect the ground screw on the back of the device with the
protective conductor before you set up the other connections. When
removing the connections, you remove the protective conductor last.
For supply voltage connections with protective conductor connection:
First connect the protective conductor before connecting the wires for
the supply voltage.
If your device comprises a second supply voltage connection of this
type: First connect the protective conductor before connecting the
wires for the supply voltages.

Table of Contents