Installation MACH1000
Release
06
03/2021
45
2.3.3 Connecting the signal contact
Relevant for North America:
The torque for tightening the terminal block for the signal contact on the
device is 3 lb-in (0.34 Nm).
Note: Use copper wire with cross-section AWG20 ... AWG12 (0.5 mm
2
...
3.0 mm
2
) and stripping length 12 mm.
For every signal contact to be connected, make sure the following
requirements are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 54.
For every signal contact to be connected, perform the following steps:
For plugged connections: connect the signal contact lines with the
terminal block connections. Mount the terminal block on the device using
screws.
To insert the cable, you open the terminal lock by positioning the
screwdriver as illustrated below and pressing on the lever.
For terminal connections: connect the signal contact lines to the
connection terminals.
Figure 17: Connecting the switching voltage via the 2-pin spring-loaded terminal
1 - Field connection terminal for switching voltage
2 - Terminal lock
1
2
Relay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH1000 Series and is the answer not in the manual?

Hirschmann MACH1000 Series Specifications

General IconGeneral
BrandHirschmann
ModelMACH1000 Series
CategorySwitch
LanguageEnglish

Related product manuals