Message Content
Error: Network error occurred,retry after a few seconds.
(PortX,Cmd:[0xXXXX],detected code[0xXXXX],error
code[0xXXXX])
What to do Check there are not any problems in a setup of a network, a LAN
switch and a connection.
Message Content
Error: Network error occurred,retry using the other port.
(Port0->Port1,Cmd:[0xXXXX],detected code[0xXXXX],error
code[0xXXXX])
Explanation Because a network error occurred, the communication port will be
switched from Port0 (Mgmt0) to Port1 (Mgmt1), and then
communication will be retried.
What to do Check there are not any problems in a setup of a network, a LAN
switch and a connection.
Message Content
Error: Notification to BMC failed.(Step:[0xXXXX],SubStep:
[0xXXXX],status:[0xXXXX],code:[0xXXXX])
Explanation Failed a noticing of an operation status to management module.
What to do Failed to access to BMC.
If this message appears as often as LPAR manager boot, contact
the reseller from which you purchased this equipment or consult
maintenance personnel.
Message Content LP-Loader could not find any network controller.
Explanation Communication NIC detection failed.
What to do Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content LP-Loader could not find HyperArea.
Explanation LP-Loader could not allocate the data area for LPAR manager
(case2).
What to do Confirm that "MM Config Base" is "2GB" in the EFI-setup menu.
When it is not "2 GB", set it to "2GB", turn off a power supply
once, and reboot the LPAR manager.
For details, see the Hitachi Compute Blade 500 series EFI User's
Guide.
Message Content
LP-Loader could not find VfcSeed.dat in management
module.
Explanation VfcSeed.dat file, having the Vfc seed information, cannot be
found in management module when the N+M was performed.
Messages
9-5
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide