Message Content
LP-Loader detected VfcSeed.dat format error.(Error Info:
0xXXXX)
0x0001: The file size is 0 byte.
0x0002: There is no key for the serial number of ChassisSeed.
0x0003: The data size of LP Serial number is 0 byte.(no data)
0x0004: Character string is included in the data of the LP Serial
number.
What to do The VfcSeed.dat file on the standby server blade may have the
format error.
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content LP-Loader recovery communication to SVP.
Explanation Communication failure is detected between LPAR manager and
Management module, therefore execute a recovery of
communication failure.
What to do When this LP System Logs is taken at every LPAR manager boots,
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content LP-Loader switched NIC port0 to port1.
Explanation Communication failure between LPAR manager and a
management module was not recovered by Port1 (MGMT1),
therefore communications processing is carried out by Port0
(MGMT0).
What to do When LP System Logs is taken at every LPAR manager boots,
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content LP-Loader updated LP Serial Number in OEM FRU.
Explanation FRU is updated when detecting N+M. (You can check that N+M
failover occurs from this message)
What to do None
Message Content LP-Loader updated VfcSeed.dat in management module.
Explanation This message is displayed when moving the server blade or
adding the server blade into the slot of the server-chassis which
operated LPAR manager in the past.
Synchronized the FRU information and the "Vfc seed information"
which is managed in management module.
What to do None.