Chapter 6 Communication mode
6 - 92
Simple data link
6.6.4 Master configuration (Initial setting of EH-SIO)
EH-SIO must be configured as simple data link mode by initial setting. (This is same as other configuration, TRNS
9 command is required for EH-SIO initial setting.) EH-SIO starts simple data link operation after initial setting.
Once initial setting is completed, EH-SIO continues simple data link operation even if CPU module is in stop mode.
To change the communication mode of EH-SIO, reboot the power or reset EH-SIO.
« Note »
EH-SIO will not receive any command from CPU module except initial setting command unless initial setting
completed.
Needed parameters for initial setting
Table 6.26 The table of parameter for initial device,
No.
Parameters
Contents
1
Communication mode
EH-SIO operation depends on selected communication mode.
Configure parameters for simple data link mode.
2
Waiting time of slave
response
Specify waiting time for slave response.
3
Waiting time between stations
Specify waiting time between stations.
4
Setting of data link area
Specify internal output I/O type and start address of data link operation.
5
Number of words occupied
by master
Specify data size (word) for master station.
6
Number of stations and words
number of each stations
Specify station number of slaves and data size (word).
s Parameters of TRNS 9 for initial setting
Initializing command (specified as s+7) is H0000.
Be sure to set parameters in the sending data area (s+9 to s+A) according to the next page, and be sure to set
dummy parameter in the receiving data area (s+B to s+D) although nothing is stored in the configured address area.
Figure 6.66 s Parameters of simple data link mode initial setting
« Note »
Although "receiving data area" is not used in simple data link mode, configure a dummy address in it.
(data in this address has nothing to do with TRNS 9 command.)
Size of receiving data area
Top I/O address of
receiving data area
Return code
H0000 (Command)
Command timeout time
Top I/O address of
sending data area
s
s+7
s+8
s+9
s+B
s+D
System area ( 6 word )