Long-term Shutdown 6-36
Com=0
Process : Process prior to
long-term shutdown
Place the ink reservoir tube connection block back
into position..
When ready, press <Start/Continue>.
Operation guide
Proc. status: In progress
Circulation control [Service     ]
Start/Continue
Proc. time : Approx. 6 minutes
2015.07.0712:45
InkDrainage
Systemclean
InkDrainage
Systemclean
InkDrainage
Systemclean
Repeat steps to once more time.
(Perform the ink drainage to clean the circulation system three times in totall.)
Mount the nozzle rubber seal.
Mount the "nozzle rubber seal" between the charge electrode and the orifice plate.
6
1. Before installing the nozzle rubber seal, be sure to thoroughly clean it with the
makeup.
2. When installing the nozzle rubber seal, exercise care not to deform the charge
electrode.
CAUTION
The "Process prior to long-term shutdown" is now completed.
The circulation system is now charged with the makeup.
When starting up the printer after a long-term shutdown, be sure to perform the "6.15.2 Startup
process after long-term shutdown."
(a) Drain the ink ejected into the beaker, clean the beaker and then put 50ml of the
makeup and a tube connection block into the beaker.
3 4
If ink is accidentally spilt, wipe it up
promptly with wiping paper or
equivalent.
In addition, do not close the
maintenance cover until you are
sure that the wiped area is
completely dried.
CAUTION
(b) Press Start/Continue .
Auto cleaning in the circulation system starts.
(c) When the predetermined period of time elapses, the following operating guidance
appears.
Place the cap and tube connection block as they were, and place the ink reservoir
back in place.
Be careful not to break the tube when mounting it into the printer.
5
Tube connection block
Beaker