2015.07.0712:45
Back
Com=0
Ink operating time
Ink alarm time
Cumulative op. time
Print count
Ink, makeup
JP-K69, TH-TYPE A
Ink viscosity 100 (standard value:100)
Ink pressure 0
.
250 (MPa; standard value: 0
.
250)
Ambient temperature 20 (
℃
; range: 0
〜
45)
Deflection voltage 5. 7 (kV)
Excitation V-ref. 11 (0
〜
19)
Excitation frequency 68. 9 (kHz)
0000
1200
000000000
000000
(hours)
(hours; standard value: 1200)
(hours)
(prints)
Operation management [Ready
]
M
Manual
HOME
Shutdown
Open the "Operation management" screen. Arbitrarily rotate the handle of
Pressure-reducing valve clockwise/counterclockwise and check if the
pressure changes. After confirming the change, adjust the valve and set the
Ink pressure to standard setting with a tolerance of 0.002.
3
A special work is required when the Ink pressure does not change by rotating the
handle of Pressure-reducing valve. Contact your local distributor.
CAUTION
The "Startup process after Long-term shutdown" is now completed.