Transmission Sequences 5-21
5.3.6-3 Example of Free layout transmission
(1) Specify Horizontal/Vertical coordinate and move
02H 1FH 24H 31H 35H 30H 30H 31H 32H 30H 32H 35H 03H
STXESC2$150012025ETX
Horizontal (X)
coordinate
Header,
classification
[Transmission result]
Print item 5: Horizontal (X) coordinate will be set to 120 and Vertical (Y) coordinate to 25.
Vertical (Y)
coordinate
02H 1FH 24H 32H 31H 31H 32H 33H 34H 35H 03H
STXESC2$2112345ETX
Horizontal (X)
coordinate
Header,
classification
[Transmission result]
Print item 1: Horizontal (X) coordinate will be set to "12345".
02H 1FH 24H 33H 94H 30H 30H 03H
STX ESC2 $ 3 100 0 0 ETX
Item No. Vertical (Y)
coordinate
Header,
classification
[Transmission result]
Print item 100: Vertical (Y) coordinate will be set to "0".