5-24 Transmission Sequences
(2) Count Conditions Transmission
ESC2 Header 2CH Classification
Count
block No.
Setting
value
Classification
Item name Setting value
31H Initial value Character code
32H Range 1 Character code
33H Range 2 Character code
34H Update setting range (In progress) 000000 to 999998
35H Update setting range (Unit) 000001 to 999999
36H Increment setting range 01 to 99
37H Direction 0: up, 1: down
38H Jump from Character code
39H Jump to Character code
3AH Reset Character code
3BH Reset signal (option) 0:signal 1, 1:signal 2
3EH External signal count (option) 0: Disable, 1: Enable
Character code of setting value
Mode Alphanumeric User pattern
1-byte mode ASCII ASCII
2-byte mode ASCII 2-byte code
Calendar block No.
(1 to 8)
*) When count characters has been divided (e.g., [ CC CC ]), transmit four-digits characters.