3
A99UE13-1304
1. While operating an actuator, don't interrupt the motor operation to avoid failures in
motor or mechanical structure.
2. Please follow the directions and use the nominal voltage of actuator motor with
DC voltage. The supplied DC voltage can provide the maximum current at the
maximum load.
3. If customers use power supplies and controllers themselves, please follow the
current allowed for wire cross-section to install over current protectors (such as
fuse), on the output end of power supplier or the input end of actuator power and
use this over current signal to control actuators, which not only stop movement
or disconnect power supply but also ensure the extension tube of an actuator at
the limit position or under the overload operation can disconnect the power and
provide appropriate control and protection.
4. Unless specially customized, the duty cycle of our actuator should be 10%. The
duty cycle is dened to continuously operate 2 minutes and pause 18 minutes. If
customers operate over duty cycle (10%), please install overheat detection and
prevention devices (as a fan) and use this overheat detection signal to control
actuators to stop movement or disconnect power supply according to control
requirements.
5. If customers don't purchase limit switches, please install the limit switches at the
stroke positions of the extension tube of an actuator yourself and combine that
limiter for power failure on controllers and power suppliers to ensure the power
can be disconnected when the extension tube of an actuator moves to the stroke
and wire position.
6. The actuator is DC driven. When the two input wires of motor power are
exchanged, the extension tube of the actuator will reversely move. Please use
proper controllers and power suppliers while stop. Two input wires of motor power
are short-circuited to provide auxiliary brake. Note that the power of actuator
motor should be disconnected and then short-circuited to avoid short circuit on
power supplier.
7. Don't operate up to the stroke limit if there are no limit switches and controllers
have no overload protection.
8. Don't apply actuators over the maximum load indicated by the specications.
9. If the actuator isn't water-proof, please follow the water-proof regulations.
10.Controller power: AC110V or AC220; the required input power is shown on the
controller's specication tag.
11.Operating temperature: +5°C ~ +40°C (+41°F ~ +104°F).
Operating Safety Regulation: