This is a heavy duty circuit breaker that typically
trips only when there is a fault in the system. If
it trips, you should nd and correct the problem
before resetting the breaker. The breaker is reset
by turning the yellow lever to the ON position.
ATC blade type fuses in the fuse panel inside the
console switch panel protect the circuits activated
by the switches. The fuses are color coded with
the AMP rating printed on the fuse. The fuse body
is translucent plastic with the fuse element clearly
visible making it easy to identify a blown fuse.
When replacing fuses, never replace the blown
fuse with a fuse of a dierent color or higher am-
perage in an attempt to correct a circuit that is
causing the fuse to blow. Using a higher amperage
fuse can cause the circuit to overheat which can
damage the circuit and components or cause an
electrical re.
Contact Hog Technologies Customer Service if you
need assistance correcting a problem with the
Stripe Hog electrical system.