[6]
Black
I-
[7]
Yellow/
black
[8]
Brown/
white
b.
INSPECTION
Measure the resistance between the terminals and be sure
that the measurements conform to the ranges shown in the
table below.
Use a tester that is equivalent to or higher than the perfor-
mance specified;
Internal resistance:
20
k
RNDC,
9
kRNAC
Be careful not to touch the metallic part of the tester probe
with your body, otherwise correct resistance value cannot
be obtained
Read the tester manufacturer's operation instructions
carefully before operation with a tester. Follow the instruc-
tions of the Service Manual. Be sure the tester's battery is
fully charged and check the meter before using the tester.
Use a
R
x
1
scale of an commercially available multime-
ter, and meter shows current flow from negative
(-)
to
positive
(+).
The meter shows current flowing one way
and not other the diode is good.
0.5
-
10
0.5
-
10 1-20
1
-
20
00
00
00 00
00
00
00
0.5
-
10
00 00
00
00
00 00
[l]
Type with 6A charge coil
[2] GRAY 1
[6] Type with 12A charge coil
[2] GRAY 1
-31
GRAY 2
\\
[
lO]?ELLOW/B LAC
K
-
[5] WHITE
Unit: k
R
Type with
6A
charge coil
[l]
Tester probe
(+)
I
[21
Gray 1
1
[31
Gray
2
1
[4]
White
1
[5]
Green
I
h
IL
!
I
[4]
White
2
-
40 2
-
40
1-20
[5]
Green
0.5
-
10
0.5
-
10 1-20
1641