3 - 9
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology bar
code below. On the Symbology Chart on page A-1, find the symbology you want
to set as high priority. Locate the Hex value for that symbology and scan the 2
digit hex value from the Programming Chart (inside back cover). Scan Save to
save your selection.
Default = None
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology bar code
below. On the Symbology Chart on page A-1, find the symbology you want to
set as low priority. Locate the Hex value for that symbology and scan the 2 digit
hex value from the Programming Chart (inside back cover).
If you want to set additional low priority symbologies, scan FF, then scan the 2
digit hex value from the Programming Chart for the next symbology. You can
program up to 5 low priority symbologies. Scan Save to save your selection.
Default = None
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low
priority symbologies, you must set the time-out period. This is the period of time
the imager will search for a high priority bar code after a low priority bar code has
been encountered. Scan the bar code below, then set the delay (from 1-3,000
milliseconds) by scanning digits from the inside back cover, then scanning Save.
Default = 500 ms.
Preferred Symbology Default
Scan the bar code below to set all Preferred Symbology entries to their default
values.
High Priority Symbology
Low Priority Symbology
Preferred Symbology Time-out
Preferred Symbology Default

Table of Contents

Other manuals for Honeywell 3820

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 3820 and is the answer not in the manual?

Honeywell 3820 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeCCD
Scanner type1D/2D
Read rate (max)270 reads/s
Maximum scan width610 mm
Pitch reading angle-65 - 65 °
Motion tolerance (cm/s)5
Light levels (direct sunlight)0 - 70000 lx
Linear (1D) barcodes supportedCPC Binary, Codabar, Code 11, Code 128, Code 32, Code 39, Code 93, EAN-13, EAN-8, GS1-128 (UCC/EAN-128), ITF-14, JAN, MSI, Pharmacode, Plessey, Telepen, U.P.C.
2D (matrix & stacked) barcodes supportedCodablock, Code 16K, Code 49, Composite Codes, Data Matrix, PDF417
Battery life16 h
Charging time4 h
Input voltage12 V
Battery voltage3.7 V
Battery capacity1800 mAh
Power consumption852 mA
Power source typeBattery, DC
Number of reads per charge57000
Power consumption (standby)1.2 W
Power consumption (typical)9.9 W
Number of batteries supported1
USB version2.0
PC connectionUSB 2.0
Wireless range10 m
Bluetooth version2.0+EDR
Connectivity technologyWireless
Product colorGray
Housing materialPlastic
Protection featuresDust resistant, Water resistant
Programming functionYes
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth165 mm
Width81 mm
Height157 mm
Weight261 g